Service Outage - Hardware Failure

Postmortem

What we have done and are doing to prevent this from happening again:

Already done

Service moved to the standby production server and checked end to end (November 22).

Backup no longer stops the service: the nightly backup now runs without pausing the service, so it can no longer leave the service stopped (November 23).

Cause of the Monday backup failure found: a configuration difference on the standby server. The correction is being applied in a scheduled maintenance window (November 23).

Status page launched: status.cannex.com, where you can check the status of CANNEX servicesat any time and subscribe to receive incident updates by email (November 23).

In progress

Alerting: we are routing service health alerts, including outage and disk-failure alerts, to our 24/7 service desk, so they are escalated for response at any hour.

Hardware repair: the manufacturer is replacing and testing the failed components, starting November 24. The server will return to service only after it has been fully repaired and tested.

Disk monitoring: we are adding monitoring of the servers' internal disks, so a failure like this is caught directly and straight away.

Recovery procedure: we are documenting and rehearsing the switch-over to the standby server, so any on-call engineer can do it quickly.

Customer communication: we are updating our customer contact lists and outage notification procedure, so affected customers hear from us first, with regular updates until service is restored.

Posted Nov 24, 2026 - 12:27 EST

Resolved

On Sunday, November 22, 2026, CANNEX services were unavailable from about 4:38 a.m. to 6:03p.m. During this time, requests to CANNEX web and API services returned errors. The outage was caused by a hardware failure on our primary production server. We restored
service by moving it to our standby production server, which is in the same data centre and was installed for exactly this situation.

Two disks failed at the same time inside our primary production server. They were a mirrored pair, so each was the backup of the other. Losing both at once is very unusual. The server stopped processing requests but did not shut down completely. Switching to the standby server is a manual step by design. This protects data integrity, because two servers must never run the service at the same time. Our engineers restarted the server, confirmed the hardware fault, and switched the CANNEX service to our standby production server as a deliberate, controlled step. Before allowing external access, we checked that the application and its data were complete and working correctly.

Availability: CANNEX web and API services were unavailable during the periods above. Requests returned errors and were not processed.
Data: no data was lost, changed or exposed. You don't need to re-submit any historical data. Requests during the outages: any request your systems sent during these periods failed and was not processed. If your process doesn't retry automatically, you may need to send those requests again. Scheduled deliveries: files and updates normally produced during the outage periods, such as rate files, may have been delayed.
Posted Nov 22, 2026 - 04:30 EST